SCREW COUPLING - POPPET QX

Female coupling - Male thread

DN 6 to 10
1/4" to 3/8"

WP 700 bar 10150 PSI
Unit of Measure
Items
Primary Image - 10,000 PSI Industry Standard Female Coupler with Male Thread

1/4 in. Inside Diameter 10,000 PSI Industry Standard Female Coupler with Male Thread

Primary Image - 10,000 PSI Industry Standard Female Coupler with Male Thread

3/8 in. Inside Diameter 10,000 PSI Industry Standard Female Coupler with Male Thread
Description N/A QD 10K 1/4" Female x 1/4" MNPT N/A QD 10K 3/8" Female x 3/8" MNPT
General Features N/A ARGUS QX high pressure couplings can be used for connecting and disconnecting hydraulic lines. Their robust construction and tested components make them ideally suited for high and intermittent pressure loads. During the coupling action, valves that release and/or block the flow are automatically activated. The QX quick release coupling, formed by coupling plug and coupling socket, is coupled by a screwing action with the hand nut of the plug component.
  • Typically employed in power tools
  • Compatibility with other couplings in-use
Materials N/A galvanized steel - HNBR O-rings (other materials optional) - Thermoplastic dust cap and dust plug. Top Coat Cr-III zinc plating with additional trivalent passivation for outstanding surface protection.
Norm N/A ISO 14540
Temperature Range [Min] N/A -30 ºC-22 ºF
Temperature Range [Max] N/A 125 ºC257 ºF
Brand N/A ALFAGOMMA®
Type N/A Female Coupler with Male Thread
Weight N/A 0.3 lb N/A 0.7 lb
Dash N/A 04 N/A 06
Inside Diameter N/A 1/4 in6.0 mm N/A 3/8 in10.0 mm
Working Pressure N/A 10150 psi
Burst Pressure N/A 40600 psi
Thread 1 N/A NPTF
F1 N/A 1/4-18 N/A 3/8-18
D1 N/A 28.5 mm N/A 35.0 mm
CH N/A 22.0 mm N/A 25.0 mm
L1 N/A 59.6 mm N/A 72.5 mm
L N/A 74.00 mm N/A 83.00 mm
End Type N/A Female
Second End Type N/A FPT
Second End Size N/A 1/4 in N/A 3/8 in
Note N/A Rated flow / pressure drop values on request. Other sizes and connection types available on request.
Specific instructions for installation, use and maintenance are separately provided.

NPTF connection according to ANSI B1-20.3.